8/19/2023 0 Comments 200 amp wire size ground![]() ![]() Then bag the 200A breaker and leave it in the bottom of the panel for that happy day in the future. The 200A version of the panel is so popular that cost wise, you are probably better off buying the 200A version of that panel, then buying a retrofit 100A main breaker for it. Only difference is you fit a 100A main breaker in the farm panel instead of 200A. Since you expect to go to 200A, I advise still doing the above. If your existing feeder to the house is only 100A, then go ahead and feed it from one of those four 2-pole brakers, just slap a 100A breaker in there (90A if the wire is #2 aluminum or #4 copper).Except my service is only 100A 50A to the RV stand (they don't need more unless there are two RV stands). Then you use the 8 breaker spaces for four 2-pole "feeder breakers" - e.g. The idea is you come off the "thru lugs" to the biggest load - e.g. "Thru Lugs" carrying the full 200A onward.8 breaker spaces (they also make 4-space versions, avoid - too few).The answer is based on NEC-2008, Sections 250.122, Table 250.122, and Chapter 9, Table 8 (conductor properties). What size ground wire is needed for a 60 amp sub panel In short, the wire size for a 60 amp sub-panel 150 feet away is 3 AWG gauge wire. The minimum size equipment grounding conductor for this 200-ampere feeder is a 4 AWG copper conductor. The minimum size for a grounding wire for 200 amp is 4 AWG copper or 2 AWG aluminum, according to Article 250 of the 2020 NEC. welding in the shed with the compressor running. According to Table 8, a 4 AWG copper is required 41,740 cm. You still want to make each feeder big enough it won't trip on its local loads e.g. But that allows for intermittent and "non-simultaneous use". You are restricted on how much total load you can have on the service, and this is based on a Load Calculation. even though these add up to more than 200A. So for instance if you have 200A service, it is OK to have 200A going to the house, 100A going to the shed, 50A to an RV stand, 30A to a well, etc. The person is incorrectly applying 310.15(B)(7) on the assumption that your entire service is 100A, and they don't even realize their blunder because they're just giving 4th generation hand-me-down advice from someone else who misapplied 310.15(B)(7).Īctually, you need #1 Al / #3 Cu for 100A, and 310.15(B)(7) is saying that you never need larger than 4/0 (which isn't very helpful lol). Now, often when you go shopping for 100A wire, some fool will tell you "oh use #2 aluminum or #4 copper". So that calculates out to 4/0 aluminum (180A). So any feeder - even if it's 200A feeder - only needs to be 166A not 200A. 10 copper wire and GRB-1 or GRB-2 copper grounding clamps to attach the outdoor LNA (low-noise amp), motor drive and discharge unit to the antenna and its. You never need to use wires larger than that anywhere that's served by that service. NEC 310.15(B)(7)says that you take your entire (planned) service size - 200A - and multiply it by. Apply 310.15(B)(7) to your entire service ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |